Re: How to replace failed drive in RAID 1(1+0) array in HP DL380 G4

$
0
0

To persons who have interest for this topic,

 

what I did yesterday is,

 

pull the failed drive(18.2,15K) and pop in a new one(72.8G 10K) without reboot.

 

Followings are output when do command :

 

#hpacuali ctrl all show config

 

Smart Array 6i in Slot 0 (Embedded)

array A (Parallel SCSI, Unused Space: 0 MB)


logicaldrive 1 (17.0 GB, RAID 1, OK)

physicaldrive 2:0 (port 2:id 0 , Parallel SCSI, 72.8 GB, OK)
physicaldrive 2:1 (port 2:id 1 , Parallel SCSI, 18.2 GB, OK)

array B (Parallel SCSI, Unused Space: 0 MB)


logicaldrive 2 (67.8 GB, RAID 1, OK)

physicaldrive 1:2 (port 1:id 2 , Parallel SCSI, 72.8 GB, OK)
physicaldrive 1:3 (port 1:id 3 , Parallel SCSI, 72.8 GB, OK)

 

We lose some disk space and disk speed(which can be ignored),I think.

 

 

 

 

 